| Unit of measurement | Vento inHome C1 L035 S15 W | |||
| Speed | - | 1 | 2 | 3 |
| Phases | - | 1 | ||
| Maximum supply voltage | V | 240 | ||
| Minimum supply voltage | V | 100 | ||
| Power supply frequency | Hz | 50/60 | ||
| Air flow in ventilation mode | m³/h | 15 | 35 | 50 |
| Air flow in heat recovery mode | m³/h | 8 | 15 | 25 |
| Sound pressure level LpA at 1 m | dB(A) | 20 | 30 | 36 |
| Heat recovery efficiency, max | % | 95 | ||
| Heat exchanger material | - | Ceramic | ||
| Transported air temperature (max) | °С | 40 | ||
| Transported air temperature (min) | °С | -20 | ||
| Ingress protection rating | - | IP24 | ||
| Trademark | Blauberg | |||||
| Model | Vento inHome C1 L035 S15 W | |||||
| Specific energy consumption (SEC) (kWh/(m²/a)) | Cold | Average | Warm | |||
| -84.7 | A+ | -42.9 | A+ | -18.9 | E | |
| Type of ventilation unit | Bidirectional | |||||
| Type of drive installed | Variable speed | |||||
| Type of heat recovery system | Regenerative | |||||
| Thermal efficiency of heat recovery (%) | 74 | |||||
| Maximum flow rate (m³/h) | 50 | |||||
| Electric power input (W) | 3.2 | |||||
| Reference flow rate (m³/s) | 0.005 | |||||
| Specific power input (SPI) (W/(m³/h)) | 0.122 | |||||
| Control typology | Local demand control | |||||
| Maximum internal leakage rates (%) | 2.7 | |||||
| Mixing rate (%) | 1 | |||||
| Airflow sensitivity at +20 Pa and -20 Pa (%) | 1.4 | |||||
| The indoor/outdoor air tightness (m³/h) | 2.3 | |||||
| Declared typology | RVU BVU | |||||
| Sound power level (dB(A)) | 37 | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 37 | 37 | 37 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 86 | 44 | 20 | ||||